logo
  • English
Home Products1.2 V Ni Cd Battery

Nicad Cell 1.2 V Ni Cd Battery D4500mAh For Emergency Lights

Certification
China Godson Technology Co., Ltd certification
China Godson Technology Co., Ltd certification
I'm Online Chat Now

Nicad Cell 1.2 V Ni Cd Battery D4500mAh For Emergency Lights

Nicad Cell 1.2 V Ni Cd Battery D4500mAh For Emergency Lights
Nicad Cell 1.2 V Ni Cd Battery D4500mAh For Emergency Lights Nicad Cell 1.2 V Ni Cd Battery D4500mAh For Emergency Lights Nicad Cell 1.2 V Ni Cd Battery D4500mAh For Emergency Lights Nicad Cell 1.2 V Ni Cd Battery D4500mAh For Emergency Lights

Large Image :  Nicad Cell 1.2 V Ni Cd Battery D4500mAh For Emergency Lights

Product Details:
Place of Origin: Guangdong, China (Mainland)
Brand Name: Godson or OEM
Model Number: Ni-Cd Battery Pack D4500mAh 1.2V
Payment & Shipping Terms:
Minimum Order Quantity: 50PCS
Price: Negotiable
Payment Terms: T/T

Nicad Cell 1.2 V Ni Cd Battery D4500mAh For Emergency Lights

Description
Type: NI-CD Size: D
Nominal Voltage: 1.2V Nominal Capacity: 4500mAh
Configuration: Stick Type Model Number: GS-D450T-A
Highlight:

D4500mAh 1.2 V Ni Cd Battery

,

Nicad Cell 1.2 V Ni Cd Battery

,

D4500mAh Ni Cd Battery Cell


Nicad Cell D4500mAh 1.2V Emergency Light Battery With Good Safety


Application:

 

Pos. Application fields Application of the product
1 Lighting emergency lighting, emergency power supply, solar lights, searchlingts, flashlights
2 Power tools electric drills, planers, saws, power granted
3 Electronic toys remote control car, remote control boats, aircraft, model aircraft
4 Communication equipment cordless phones, walkie-talkie
5 Other uses electric shavers, massagers, electric tooth brush



Product parameters:
 

Standard Charge Mode: 0.1C for 16 hours

Cycle Life: ≥500 times

Operating Temperature: (-20℃) - (+70℃)

Storage Temperature: (-30℃) - (+60℃)

Expected Life: 5 years

Packaging: Standard export package or customized package.


List Of Ni-CD High Temperature Cells:
 

Ni-Cd battery has high charge and discharge efficiency and good safety performance at high temperature and has long service life under condition of long term floating charge, which makes it very suitable for emergency lighting application.

 

Working temperature for Ni-Cd battery could be up to 55 degree, and even up to 70 degree, and expected service life could be up to 4 to 5 years.

Type Model Diemeter
(mm)
Height
(mm)
Capacity
(mAh)
Voltage
(V)
Operating Temperature
(°C)
AAA GS-AAA30T 10.5 +0 -0.7 43.0 ±0.5 300 1.2 -20 to 70
GS-AAA30 10.5 +0 -0.7 43.0 ±0.5 300 1.2 -20 to 55
GS-AAA35 10.5 +0 -0.7 43.0 ±0.5 300 1.2 -20 to 55
AA GS-AA800T 14.5 +0 -0.7 50.0±0.5 800 1.2 -20 to 70
GS-AA80 14.5 +0 -0.7 50.0±0.5 800 1.2 -20 to 55
GS-AA90T 14.5 +0 -0.7 50.0±0.5 900 1.2 -20 to 70
GS-AA90 14.5 +0 -0.7 50.0±0.5 900 1.2 -20 to 55
GS-AA100 14.5 +0 -0.7 50.0±0.5 1000 1.2 -20 to 55
GS-AA110 14.5 +0 -0.7 50.0±0.5 1100 1.2 -20 to 55
A GS-4/5A110T 17.0 +0 -0.7 42.5±0.5 1100 1.2 -20 to 70
GS-4/5A110 17.0 +0 -0.7 42.5±0.5 1100 1.2 -20 to 55
GS-4/5A120T 17.0 +0 -0.7 42.5±0.5 1200 1.2 -20 to 70
GS-4/5A120 17.0 +0 -0.7 42.5±0.5 100 1.2 -20 to 55
GS-A130T 17.0 +0 -0.7 49.5±0.5 1300 1.2 -20 to 70
GS-A130 17.0 +0 -0.7 49.5±0.5 1300 1.2 -20 to 55
GS-A140 17.0 +0 -0.7 49.5±0.5 1300 1.2 -20 to 55
SC GS-4/5SC120T 23.0 +0 -1.0 33.5±0.5 1200 1.2 -20 to 70
GS-SC120T 23.0 +0 -1.0 42.5±0.5 1200 1.2 -20 to 70
GS-SC120 23.0 +0 -1.0 42.5±0.5 1200 1.2 -20 to 55
GS-SC130T 23.0 +0 -1.0 42.5±0.5 1300 1.2 -20 to 70
GS-SC130 23.0 +0 -1.0 42.5±0.5 1300 1.2 -20 to 55
GS-SC140T 23.0 +0 -1.0 42.5±0.5 1400 1.2 -20 to 70
GS-SC140 23.0 +0 -1.0 42.5±0.5 1400 1.2 -20 to 55
GS-SC150T 23.0 +0 -1.0 42.5±0.5 1500 1.2 -20 to 70
GS-SC150 23.0 +0 -1.0 42.5±0.5 1500 1.2 -20 to 55
GS-SC160T 23.0 +0 -1.0 42.5±0.5 1600 1.2 -20 to 70
GS-SC160 23.0 +0 -1.0 42.5±0.5 1600 1.2 -20 to 55
GS-SC170T 23.0 +0 -1.0 42.5±0.6 1700 1.2 -20 to 70
GS-SC170 23.0 +0 -1.0 42.5±0.6 1700 1.2 -20 to 55
GS-SC180T 23.0 +0 -1.0 42.5±0.5 1800 1.2 -20 to 70
GS-SC180 23.0 +0 -1.0 42.5±0.5 1800 1.2 -20 to 55
GS-SC190T 23.0 +0 -1.0 42.5±0.5 1900 1.2 -20 to 70
GS-SC190 23.0 +0 -1.0 42.5±0.5 1900 1.2 -20 to 55
GS-SC200T 23.0 +0 -1.0 42.5±0.5 2000 1.2 -20 to 70
GS-SC200 23.0 +0 -1.0 42.5±0.5 2000 1.2 -20 to 55
GS-SC210 23.0 +0 -1.0 42.5±0.5 2100 1.2 -20 to 55
C GS-C220T 25.8 +0 -1.0 49.5±0.5 2200 1.2 -20 to 70
GS-C220 25.8 +0 -1.0 49.5±0.5 2200 1.2 -20 to 55
GS-C250T 25.8 +0 -1.0 49.5±0.5 2500 1.2 -20 to 70
GS-C250 25.8 +0 -1.0 49.5±0.5 2500 1.2 -20 to 55
GS-C280T 25.8 +0 -1.0 49.5±0.5 2800 1.2 -20 to 70
GS-C280 25.8 +0 -1.0 49.5±0.5 2800 1.2 -20 to 55
GS-C300T 25.8 +0 -1.0 49.5±0.5 3000 1.2 -20 to 70
GS-C300 25.8 +0 -1.0 49.5±0.5 3000 1.2 -20 to 55
D GS-D400T 33.0 +0 -1.0 60.0+0 -1.5 4000 1.2 -20 to 70
GS-D400 33.0 +0 -1.0 60.0+0 -1.5 4000 1.2 -20 to 55
GS-D450T 33.0 +0 -1.0 60.0+0 -1.5 4500 1.2 -20 to 70
GS-D450 33.0 +0 -1.0 60.0+0 -1.5 4500 1.2 -20 to 55
GS-D500T 33.0 +0 -1.0 60.0+0 -1.5 5000 1.2 -20 to 70
GS-D500 33.0 +0 -1.0 60.0+0 -1.5 5000 1.2 -20 to 55
GS-1/2D220T 33.0 +0 -1.0 36.0 +0 -1.5 2200 1.2 -20 to 70
GS-1/2D220 33.0 +0 -1.0 36.0 +0 -1.5 2200 1.2 -20 to 55
GS-1/2D250 33.0 +0 -1.0 36.0 +0 -1.5 2500 1.2 -20 to 55
F GS-F700T 33.0 +0 -1.0 90.0 +0 -1.5 7000 1.2 -20 to 70
GS-F700 33.0 +0 -1.0 90.0 +0 -1.5 7000 1.2 -20 to 55

 

 

Ni-Cd Battery Cell Performance:
 

1. Ni-Cd Cell Charge Curve At 0.1C For 16h At 55 Degree

 

Nicad Cell 1.2 V Ni Cd Battery D4500mAh For Emergency Lights 0
 

2. Ni-Cd Cell Discharge Curve At 0.25C At 55 Degree

 

Nicad Cell 1.2 V Ni Cd Battery D4500mAh For Emergency Lights 1
 

3. Ni-Cd Cell Charge Efficiency At Different Temperature

 

Nicad Cell 1.2 V Ni Cd Battery D4500mAh For Emergency Lights 2

4. Ni-Cd Cell Capacity Change At Permanent Charge At 55 Degree (0.05C Floating)

 

Nicad Cell 1.2 V Ni Cd Battery D4500mAh For Emergency Lights 3

 

5. Ni-Cd Cell Cycle Life Curve

 

Nicad Cell 1.2 V Ni Cd Battery D4500mAh For Emergency Lights 4

 

Contact Details
Godson Technology Co., Ltd

Contact Person: Paul Huang

Tel: +86 134 3021 3452

Fax: 86-20-2986-1459

Send your inquiry directly to us (0 / 3000)